ETECH EH LKD Intelligent Pressure Group up to 7.0 m3/h

VER PREÇO / COMPRAR
Etech
Product Name Price Delivery Qty
Etech-Franklin EH5-4, 230V, LKD Speed Variation
Cód.ETEEH05-04LKD
€1,145.85
Etech-Franklin EH5-5, 230V, LKD Speed Variation
Cód.ETEEH05-05LKD
€1,202.60
Etech-Franklin EHsp 5-4, 230V, LKD Speed Variation
Cód.ETEEHsp05-04LKD
€1,165.60
Etech-Franklin EHsp 5-5, 230V, LKD Speed Variation
Cód.ETEEHsp05-05LKD
€1,226.10

Product Description

Integrated system with ETECH multistage centrifugal electric pumps and speed variation control.

Features of the E-Tech EH electric pump:
Horizontal multistage centrifugal electric pumps completely made of stainless steel.
Body, impellers and diffusers in AISI 304.
EHsp self-priming version.
Liquid temperature between -15ºC and 90ºC (domestic use, +110ºC industrial use).
Maximum ambient temperature 40ºC.
PPS floating rings
STD mechanical seal type E0 (Ceramic/Graphite/EPDM)
50Hz 2-pole asynchronous motor, TEFC, class F insulation, IP55 degree of protection
IE3 efficiency three-phase motors Compact pressure group for an electric pump to work with constant pressure in domestic and commercial applications

LKD-4500N frequency inverter for pumping systems

The control of surface electric pumps by the LKD-4500N variator guarantees:
Constant pressure regulation
Energy savings
Silent system
Electric pump and system protection
Easy installation, configuration and start-up
Full integration with the electric pump

This system constantly modulates the speed of the electric pump and uses only the energy essential for this purpose. In addition to reducing energy consumption, it increases the durability of the electric pump, as its mechanics are not always subjected to maximum speed and do not produce shock effects. ram since the starts and stops are progressive. This equipment stands out for its simplicity of programming and use, after connecting to the mains you only have to set the nominal pressure.

Features of the integrated system
Single-phase electrical supply 230V 50Hz
Three-phase output 3~230V 50Hz
Pressure sensor 0-16 bar included
Schuko type plug
Compact equipment
Wiring and factory configured
Ready to put into operation

Specification

Connections
Suction: 11/4"
Compression: 1"

EH series 5
Model

Input Voltage

[V]

Engine - I [A]

P1 P2 Q
3 ~230v [kW] [kW] [HP] l/min 0 33 42 50 58 67 75 83 92 100 117
m3 /h0 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 7.0
H [m]
EH 5/4 1~230V 3.2 0.99 1.10 1.50 46.2 42.4 41.1 39.9 38.5 37 35.2 33.2 30.9 28.4 21.9
EH 5/5 1~230V 3.7 1.21 1.10 1.50 57.3 52.1 50.4 48.8 47 45 42.7 40.1 37.2 34 25.8
EHsp 5/4 1~230V 3.2 0.99 1.10 1.50 45 41.5 40 39 37 36 34 32 30 26.5 20
EHsp 5/5 1~230V 3.7 1.21 1.10 1.50 55.5 51 49 47.5 45.5 43 41 38 35 31.5 23