Fairland INVERX heat pump

VER PREÇO / COMPRAR
Fairland
Product Name Price Delivery Qty
IXR36 -13KW
Cód.ECO811135013

€4,182.00

€3,178.32

IXR46 - 17KW
Cód.ECO811135015

€5,264.40

€4,212.00

IXR56 - 21KW
Cód.ECO811135014

€6,138.00

€4,665.00

IXR66 - 26KW
Cód.ECO811135016

€6,827.00

€5,189.00

IXR80T - 32KW
Cód.ECO811135017

€8,094.00

€6,151.00

IXR110T - 40KW
Cód.ECO811135018

€9,213.00

€7,000.00

Product Description

Fairland INVERX Heat Pump

After five years of research and development, Fairland presents its new InverX heat pumps equipped with TurboSilence technology. An incremental improvement over Full-Inverter technology, TurboSilence technology provides the perfect balance between inverter compressor control and heat exchange, thus enabling market-leading performance at a minimum noise level.


Silent

10x less noise than a common inverter pump .
Unique technology where the compressor does not produce high frequency noise.
Calm surrounding and swimming environment.


Turbo

COP 50 to 70% higher than common inverter pumps at maximum power.
Up to 20% faster heating at a higher efficiency level.
An average operation at 50% is sufficient to maintain the pool temperature.


Highlights

  • Integrated control system for fewer breakdowns and easier servicing;
  • Unique porous design that facilitates ventilation, allowing for better heat exchange, resistance and durability;
  • Smart control panel with WI-FI controller included;
  • Four-season operation, -15 to 43ºC ;
  • Includes roof and silent blocks.

Specification

TECHNICAL CHARACTERISTICS

MODELS

IXR36

IXR46 IXR56 IXR66 IXR8T IXR110T
PERFORMANCE: AIR 26ºC / WATER 26ºC / HUMIDITY 80%
POWER DELIVERED SMART MODE kW 11 14 18 22 27.5 33
POWER DELIVERED TURBO MODE kW 13 17 21.5 26 32 40
COP 12 11.5 11.5 11.6 11.5 11.4
PERFORMANCE: AIR 15ºC / WATER 26ºC / HUMIDITY 70%
POWER DELIVERED SMART MODE kW 9 11.5 14.5 18 22 28.5
POWER DELIVERED TURBO MODE kW 7.5 9.5 12 15 18.5 24.5
ABSORBED POWER kW 0.22 - 1.8 0.26 - 2.56 0.31 - 3.08 0.38 - 3.53 0.46 - 4.4 0.6 - 5.94
COP 7 - 5 7.5 - 4.5 8 - 4.7 8 - 5.1 8 - 5 8.1 - 4.8
TECHNICAL CHARACTERISTICS
MAXIMUM POOL VOLUME m 3 25 - 50 30 - 60 40 - 75 55 - 100 65 - 120 90 - 160
RECOMMENDED AVERAGE FLOW RATE m 3 /H 3 - 4 4 - 6 6.5 - 8.5 8 - 10 10 - 12 12 - 18
HYDRAULIC CONNECTION Ø50
POWER SUPPLY 230V/1/50Hz 400V/3/50Hz
NOMINAL ABSORBED INTENSITY THE 7.82 11.3 13.4 15.3 6.35 8.57
MAXIMUM ABSORBED INTENSITY THE 10 15 19 8 28 10
POWER CABLE SIZE 3 x 2.5 5 x 2.5 3 x 6 5 x 2.5
COOLANT FLUID RS2 R410A
REFRIGERANT FLUID AMOUNT Kg 1,2 1.3 1.45 1.8
ACOUSTIC POWER dB(A) 64/61 65/63 66/63 68/66 64/61 65/62
ACOUSTIC PRESSURE AT 10m dB(A) 18.6 - 26.9 22.0 - 27.7 22.9 - 27.7 20.8 - 311.2 23.3 - 31.9 22.5 - 31.7
WEIGHT Kg 61 63 70 90 99 120
DIMENSIONS 893x432x650 939x432x650 995x432x750 1125x429x952 1074x539x947 1260x539x947

Documents